500 gallon oil water separator

To : Flemington Precast & Supply, L.L.C.


I would like to disclose my contact information to Flemington Precast & Supply, L.L.C.

I would like to request the following information about:

More info about your company.

Your Diversity Classifications.

Information about a product or service.

Your testimonials and ratings.

Your bonding information.

Your safety record and training.

More images or a specific type of image.

Your financial references.


Do you have any other special instructions, requests or details?

Is your order time-sensitive? Send us an email or call us to see which suppliers are experiencing material shortages or delayed shipping times.


500 gallon oil water separator

*Image is a representation of this item. Actual item may vary.*
Hover over image to zoom


500 gallon oil water separator
 
500 gallon oil water separator


Containment Solutions AOWS - Double Wall Double-Wall Above Ground Steel Oil/Water Separator Tanks

100 to 2,500 Gallons, 10 to 250 GPM, 1 in. to 8 in. Inlet/Outlet (10 PPM effluent quality)


Ships from Manufacturer

Select Model & Quantity:

Model#

Description

Price

Qty

AOWS-10 Double Wall

100 Gallon (20 gal. Oil Storage - 50 gal. Oil Spill), 10 GPM, Dim. 4 ft. 10 in. x 2 ft. 3 in. x 3 ft. 7 in.

$13,308.90

AOWS-25 Double Wall

250 Gallon (50 gal. Oil Storage - 125 gal. Oil Spill), 25 GPM, Dim. 6 ft. 10 in. x 2 ft. 3 in. x 3 ft. 7 in.

$16,883.10

AOWS-50 Double Wall

500 Gallon (100 gal. Oil Storage - 250 gal. Oil Spill), 50 GPM, Dim. 8 ft. 4 in. x 3 ft. 3 in. x 3 ft. 7 in.

$24,575.40

AOWS-75 Double Wall

750 Gallon (150 gal. Oil Storage - 375 gal. Oil Spill), 75 GPM, Dim. 10 ft. 10 in. x 3 ft. 9 in. x 3 ft. 7 in.

$28,454.85

AOWS-100 Double Wall

1,000 Gallon (200 gal. Oil Storage - 500 gal. Oil Spill), 100 GPM, Dim. 11 ft. 10 in. x 3 ft. 9 in. x 4 ft. 7 in.

$33,771.75

AOWS-150 Double Wall

1,500 Gallon (300 gal. Oil Storage - 750 gal. Oil Spill), 150 GPM, Dim. 11 ft. 1 in. x 5 ft. 3 in. x 4 ft. 7 in.

$38,400.45


500 gallon oil water separator

  1. Home
  2. Large Capacity Oil Interceptors (ROI Series)

500 gallon oil water separator

Large Capacity Oil Interceptor

150 Gallon Capacity

500 gallon oil water separator

Large Capacity Oil Interceptor

250 Gallon Capacity

500 gallon oil water separator

Large Capacity Oil Interceptor

350 Gallon Capacity

500 gallon oil water separator

Large Capacity Oil Interceptor

500 Gallon Capacity

500 gallon oil water separator

Large Capacity Oil Interceptor

750 Gallon Capacity

** Exceeds Lift Gate Capacity **

500 gallon oil water separator

Large Capacity Oil Interceptor

1000 Gallon Capacity

** Exceeds Lift Gate Capacity **

500 gallon oil water separator

Large Capacity Oil Interceptor

1250 Gallon Capacity

** Exceeds Lift Gate Capacity **

500 gallon oil water separator

Large Capacity Oil Interceptor

1500 Gallon Capacity

** Exceeds Lift Gate Capacity **

How do you size an oil water separator?

As a rule of thumb, some experts recommend a ten minute retention time in a gravity oil water separator. To achieve this, the separator chamber should be sized at ten times the flow rate. For example, a 1,000-litre chamber is recommended for a flow rate of 100 litres per minute.

What are the different types of oily water separator?

Types of Water Oil Separator Systems.
Conventional Gravity Separators (API) Conventional gravity separators use the force of gravity to separate oil and other contaminants from water. ... .
Parallel Plate Gravity Separators. ... .
Hydrocyclone Water Oil Separator System. ... .
Flotation Separators..

What are the 3 main components of an oily water separator?

OWS consists of mainly three segments:.
Separator unit. This unit consists of catch plates which are inside a coarse separating compartment and an oil collecting chamber. ... .
The Filter unit. This is a separate unit whose input comes from the discharge of the first unit. ... .
Oil Content Monitor and Control Unit..

Where are oil separators required?

An oil separator is required only where floor or trench drains are present. It is not assumed that oil bearing waste will be introduced into the drainage system through plumbing fixtures other than floor drains and trench drains.