Modern refrigeration and air conditioning 21st edition quizlet

Show
    Recommended textbook solutions

    Modern refrigeration and air conditioning 21st edition quizlet

    Atkins Physical Chemistry

    10th EditionJulio de Paula, Peter Atkins

    1,315 solutions

    Modern refrigeration and air conditioning 21st edition quizlet

    Atkins Physical Chemistry

    10th EditionJulio de Paula, Peter Atkins

    1,315 solutions

    Modern refrigeration and air conditioning 21st edition quizlet

    양자화학

    2nd EditionDonald A. McQuarrie

    285 solutions

    Modern refrigeration and air conditioning 21st edition quizlet

    Chimica Fisica: Un Approccio Molecolare

    1st EditionDonald Allan McQuarrie, John D. Simon

    139 solutions

    Recommended textbook solutions

    Modern refrigeration and air conditioning 21st edition quizlet

    Introduction to Chemical Engineering Thermodynamics

    7th EditionHendrick Van Ness, J.M. Smith, Michael Abbott

    582 solutions

    Modern refrigeration and air conditioning 21st edition quizlet

    Chemistry for Engineering Students

    2nd EditionLawrence S. Brown, Thomas A. Holme

    945 solutions

    Modern refrigeration and air conditioning 21st edition quizlet

    Advanced Engineering Mathematics

    10th EditionErwin Kreyszig

    4,134 solutions

    Modern refrigeration and air conditioning 21st edition quizlet

    Engineering Circuit Analysis

    9th EditionJack E. Kemmerly, Steven M. Durbin, William H. Hayt

    785 solutions

    A burnout is a condition in which the insulation of an electric motor deteriorates due to over heating.

    A restricted condenser, a large heat load on the evaporator, or a high-side restriction may all result in a high-pressure cut-out and motor overheating. In time, the condition could lead to burnout and and a motor winding short. The breakdown of motor windings causes contamination or burning or the refrigerant oil. Such oil becomes acidic.

    To prevent acid formation, a refrigeration system must be kept free of moisture and contaminants. Condensers should be regularly cleaned and checked for obstruction-free airways to prevent high head pressure.

    Home

    Subjects

    Expert solutions

    Create

    Log in

    Sign up

    Upgrade to remove ads

    Only ₹2,287/year

    • Flashcards

    • Learn

    • Test

    • Match

    • Flashcards

    • Learn

    • Test

    • Match

    Terms in this set (34)

    When replacing and old polychlorinated Biphenyl Dielectric ( PCB ) capacitor the old capacitor must be disposed of _______

    1. with common trash in the dumpster
    2. Dispose of by burning
    3. Return for deposit
    4. Dispose based on local environmental laws

    Answer 4

    MRAC page 403 20th edition ???

    In absorption refrigeration systems lithium bromide is used as the refrigerant. What is the maximum percentage by weight of lithium bromide before crystallization will begin at temperatures below 110 F

    1. 35 %
    2. 45 %
    3. 55 %
    4. 65 %

    Answer 4

    Page 890, 21st edition

    What is the purpose of the external equalizer in a thermostatic expansion valve ?

    1. Compensates for pressure drop in the evaporator
    2. Keeps the valve from hunting when full load conditions are present.
    3. Stops slugging during light load conditions
    4. Makes superheat adjustment more accurate

    Answer 1 page 479 , 21th edition

    What is the proper way to size a liquid receiver for a commercial refrigeration or air conditioning system?

    1. Sized to hold 50% of the refrigerant charge
    2. sized to hold 75 % of the refrigerant charge
    3. Size to hold 115 % of the refrigerant charge
    4. Sized to hold 125 % of the refrigerant charge

    Answer 3 page 1347, 21st edition

    The highest Temp at which substance may be liquefied, regardless of pressure applied upon it called ____ ?

    1. Enthalpy
    2. Entropy
    3. Critical pressure
    4. Critical temperature

    Answer 4 page 73, 21st edition

    32 F is equal to ____ Rankin degrees ?

    1. 32 degrees
    2. 0 degrees
    3. 273 degrees
    4. 492 degrees

    Answer 4 page 59, 21st edition

    A 12 psig pneumatic control system has an operating pressure range of ___ PSIG to ____ psig ?

    1. 0 - 12 psig
    2. 3 - 15 psig
    3. 5 - 17 psig
    4. 7 - 15 psig

    Answer 2 page 840, 21st edition

    What is the refrigerant code number for nitrogen ?

    1. R - 407C
    2. R - 770
    3. R - 744
    4. R- 728

    Answer 4 page 178 21st edition

    Wat is the most rapid method of adding refrigerant to a semi- hermetic compressor ?

    1. Valve off compressor and add oil with a refrigerant oil pump
    2. Remove the suction service valve and pour in oil
    3. Draw a slight vacuum on the crankcase by closing suction service valve and draw through with a hose or tube.
    4. Oil should never be added to a compressor.

    Answer 3 page 1466, 21st edition

    What is the allowable pressure drop across a suction line filter drier when used for air conditioning duty ?

    1. 6 psi
    2. 8 psi
    3. 10 psi
    4. Minimal

    Answer 4 page 550, 21st edition

    What is the minimum test pressure for refrigerant pipe installations when using air - cooled equipment and R -410A refrigerant ?

    1. 169 psig
    2. 278 psig
    3. 449 psig
    4. 302 psig

    Answer 3 Page 1375, 21th edition

    When fuel oil is subjected to excess vacuum it begins to ______

    1. thicken
    2. lose viscosity
    3. foam
    4. explode

    Answer 3 page 1134, 21st edition

    What is a typical application of the vortex tube cooling principals ?

    1. Aircraft cooling
    2. Industrial process cooling
    3. Welding operations
    4. Protective suits

    Answer 4 page 1287, 21st edition

    The cooling of a liquid refrigerant below its condensing temperature.

    1. Sublimation
    2. Subcooled
    3. Subtricate
    4. Isotropic

    Answer 2 page 66 21st edition

    A three - phase air handler motor is running backwards, how is the rotation changed ?

    1. Reversing the high voltage and low voltage # 2 taps
    2. Changing any two phase conductor leads
    3. Must change the motor
    4. Spin the motor 180 degrees in the mount

    Answer 2 page 325, 21st edition

    When installing a thermostatic expansion valve sensing bulb on a vertical suction line, The bulb should be mounted so the capillary tube entering the sensing bulb is ______ ?

    1. At the top
    2. at the bottom
    3. It does not matter
    4. Never mouton a vertical suction line

    Answer 1 page 483, 21st edition

    A temperature of 40 C is equal to ___ F ?

    1. 40 F
    2. 52 F
    3. 62 F
    4. 104F

    Answer 4 page 59, 21st edition

    The term " Dirty sock syndrome " refers to ?

    1. Mold odors in bathroom ducts
    2. Odors associated with water carryover from heat pump coils
    3. An odor that occurs in the heat pump during the heating and defrost cycle .
    4. A condition found when homes are left vacant for long periords

    Answer 3 page, 1075 21st edition

    _________ is used primarily in square and rectangular ducts to restrict or completely shut-off the flow of air to a room or zone ?

    1. Volume damper
    2. Manual damper
    3. Multi Blade Damper
    4. Splitter damper

    Answer 3 page 739, 21st edition

    How many BTU of heat energy is required to melt 2000 pounds of ice in a 24 - hour period ?

    1. 12,000 btu
    2. 36,000 btu
    3. 125,000 btu
    4. 288,000 btu

    Answer 4 page 66, 21st edition

    Many room air conditioners use ________ compressors.

    1. Rotary compressors
    2. Permanent split - Capacitor motors
    3. Scroll compressors
    4. Capacitor - start capacitor- run compressors

    Answer 2 page 786, 21st

    When internally insulating metal rectangular duct, how much glue coverage is recommended on the metal duct before the insulation is applied.

    1. 50 % coverage
    2. Glue manufactures directions
    3. Insulation manufactures directions
    4. 100 % coverage

    Answer 3 page 735, 21st edition

    Line voltage thermostats may control loads up to ___ amps.

    1. 10 amps
    2. 18 amps
    3. 20 amps
    4. 22 amps

    Answer 4 page 923, 21st edition

    A systems control differential is the difference between _____________.

    1. Heat in and heat out
    2. Cut- out and cut in
    3. Balance point
    4. Controlled variable and setpoint

    Answer 2 Page 339, 21st edition

    What is the difference between brazing and soldering .

    1. Filler metal is harder
    2. Filler metal is softer
    3. Soldering is for plumbing pipe joints
    4. Filler material melting point

    Answer 4 page 146, 21st edition

    What is the purpose of flux.

    1. To keep pipe and tube joints clean
    2. prevents oxidation
    3. Assures adhesion
    4. Used only for plumbing fitting and pipe

    Answer 2 page 146, 21st edition

    How many cubic feet of volume does one pound of standard are occupy ?

    1. 5.05 cubic feet
    2. 13.454 cubic feet
    3. 16.99 cubic feet
    4. 1.0 cubic foot

    Answer 2 page 55, 21st edition

    The _____ point is where wax separates from refrigerant oil.

    1. wax point test
    2. Separation point
    3. Floc point
    4. Pour point

    Answer 3 page 179, 21st edition

    ________ is the instantaneous evaporation of liquid refrigerant that cools the remaining refrigerant to the desired evaporator temperature.

    1. Flash gas
    2. Superheat
    3. sub cooling
    4. Evaporation

    Answer 1 page 91, 21st edition

    A refrigerant designed to replace R - 22 that consists of 23 %, R-22, 25 %, R -32, 25 %, R 125 and 52 % R-132 a

    1. R-410 A
    2. R 407c
    3. R -507 C
    4. R - 404 a

    Answer 2 page 174, 21st edition

    When installing vibration isolators, there location should be _______ ?

    1. Within 8 inches of the compressor
    2. within 12 inches of the compressor
    3. anywhere near the compressor
    4. as close as possible to the compressor

    Answer 4 page 462, 21st edition

    A ______ delivers a concentrated airstream into a room ?

    1. Grill
    2. diffuser
    3. Register
    4. Supply outlet

    Answer 3 page 738, 21st edition

    to control vibration when compressors with spring isolators are use, the isolators should be ______ ?

    1. kept fully seated
    2. The bolts completely removed
    3. the bolts backed out to provide clearance
    4. Rubber pads shall be installed under the unit

    Answer 3 Page 1364, 21st edition

    When brazing refrigerant lines to equipment, what precautions should be taken ?

    1. keep a fire extinguisher readily accessible
    2. use a Brazing shield
    3. use a wet quenching cloth
    4. use heat absorbing paste

    Answer 2 page 1365, 21st edition

    Sets with similar terms

    목요일 5과

    45 terms

    quizlette2297126

    777 - Navigation

    56 terms

    danielatwell

    Physical Training

    20 terms

    Cleoj607

    B777 - Communication - Updated

    27 terms

    krayw

    Sets found in the same folder

    Technical exam 1 Hvac

    46 terms

    Juan_Alvarado24

    Technical test 2 HVAC

    53 terms

    Juan_Alvarado24

    Technical test 3

    45 terms

    Juan_Alvarado24

    Laws and Rules Questions

    10 terms

    Juan_Alvarado24

    Other sets by this creator

    SC HVAC EXAM

    24 terms

    Juan_Alvarado24

    section 17 - residential/light commercial based on…

    98 terms

    Juan_Alvarado24

    business test II

    50 terms

    Juan_Alvarado24

    Business Test 1

    50 terms

    Juan_Alvarado24

    Other Quizlet sets

    Chapter 11, 12, 13: Middle Childhood

    24 terms

    bethany_dahl5PLUS

    Ch 2 - Atoms, Bonds, Acids, Base, Molecu…

    36 terms

    ariel_endsley

    PSYC 2050 Midterm

    159 terms

    ostermac

    Permit Test

    27 terms

    eddie_cundiff